High-Performance Liquid Chromatography Rheodyne Injector 7725 i (USA) Manufacturer,Supplier and Exporter in China
Product Code : EL-CE-13278
Quick answer: Features Self-priming pump head requires no manual priming Patented “Floating Pump Seal” designed for extended seal wear Available with micro, analytical, semi-prep, and prep pump heads Programmable solvent compressibility compensation Easy maintenance and service for all wetted parts Integral prime/purge assemble for quick solvent change Technical Specifications (UV Detector) Wavelength : 190-700nm Spectral bandwidth : 6 nm Wavelength Accuracy : ≤±1 nm Flow pool volume : 10μl Wavelength Reproducibility : ≤± 0.5 nm Optical path : 10 mm Dynamic Noise : ≤±2.5×10-5 AU (Methanol,1ml/min,254nm, 20°C) Static Noise : ≤± 1×10-5 AU (Empty pool, Response time 1 s, 20 °C) Dynamic Drifting : ≤± 2.5×10-4 AU (Methanol, 1ml/min, 254nm, 20°C) Static Drifting : ≤± 1×10-4 AU (Empty pool, Response time 1 s, 20 °C) Qualitative repeatability : RSD ≤ 0.1% Quantitative repeatability : RSD ≤ 0.5% Dimensions : 160H x 260W x 350 D, (mm) Weight. : 6kg Operating Temperature : 4-40°C Minimum detection concentration : ≤ 1 × 1 0 - 8 g / m L ( Naphthalene/methanol solution) Linear range : ≥104 Technical Specifications (PUMP) Flow Range : 0.001-0.999ml/min Delivery method : Double piston(Main & Auxiliary) Pump Head : 10m1 SST/Peek analytical Accuracy : ± 1% or ±2μl/min, whichever is greater ± 1% or ± 1μl/min, whichever is greater (Micro) Flow rate settings : 0-0.10 mL/min. 0.001 inc.
Features
Self-priming pump head requires no manual priming
Patented “Floating Pump Seal” designed for extended seal wear
Available with micro, analytical, semi-prep, and prep pump heads
Programmable solvent compressibility compensation
Easy maintenance and service for all wetted parts
Integral prime/purge assemble for quick solvent change
Technical Specifications (UV Detector)
Wavelength : 190-700nm
Spectral bandwidth : 6 nm
Wavelength Accuracy : ≤±1 nm
Flow pool volume : 10μl
Wavelength Reproducibility : ≤± 0.5 nm
Optical path : 10 mm
Dynamic Noise : ≤±2.5×10-5 AU (Methanol,1ml/min,254nm, 20°C)
Static Noise : ≤± 1×10-5 AU (Empty pool, Response time 1 s, 20 °C)
Dynamic Drifting : ≤± 2.5×10-4 AU (Methanol, 1ml/min, 254nm, 20°C)
Static Drifting : ≤± 1×10-4 AU (Empty pool, Response time 1 s, 20 °C)
Qualitative repeatability : RSD ≤ 0.1%
Quantitative repeatability : RSD ≤ 0.5%
Dimensions : 160H x 260W x 350 D, (mm)
Weight. : 6kg
Operating Temperature : 4-40°C
Minimum detection concentration : ≤ 1 × 1 0 - 8 g / m L ( Naphthalene/methanol solution)
Linear range : ≥104
Technical Specifications (PUMP)
Flow Range : 0.001-0.999ml/min
Delivery method : Double piston(Main & Auxiliary)
Pump Head : 10m1 SST/Peek analytical
Accuracy : ± 1% or ±2μl/min, whichever is greater ± 1% or ± 1μl/min, whichever is greater (Micro)
Flow rate settings : 0-0.10 mL/min. 0.001 inc. 0-0.0.90 mL/min. 0.010 inc. 1.0 mL/min. + 0.10 inc.
Precision : 0.25% from 0.1 mL/min. to 10 mL/min. at 20 deg C 0.25% from 0.05 mL/min. to 4 mL/min. at 20 deg C (Micro)
Pmax : 6000psi
System Connections : 1/16’ capilliaries
Dimensions : 410mm x 180mm x 270mm
Weight : 7.3kgs
Power Input : 85 to 264 VAC, 47 to 63 Hz, 60 Watts
Display : 320mm
Control : Stand alone mode using front panel
Related Products
See also Chemicals Balance, Spatula Chatway Type, Metallic, Peltier Temperature Controller With Sipper System from the same Chemistry Equipments range.
Related Categories
Exact technical specifications, materials and certifications should be confirmed with our team before ordering. Models are updated from time to time, so please contact us for the current product datasheet.