Helmholtz Coils for Use with Fine Beam Tube Manufacturer,Supplier and Exporter in China

Helmholtz Coils for Use with Fine Beam Tube

Product Code : SCL-AAN-11398
Science Lab Supplies is a leading Helmholtz Coils for Use with Fine Beam Tube Manufacturer,and suppliers in China, Helmholtz Coils for Use with Fine Beam Tube Manufacturer,and suppliers in South Africa, Helmholtz Coils for Use with Fine Beam Tube Algeria (Algiers), Helmholtz Coils for Use with Fine Beam Tube Angola (Luanda), Helmholtz Coils for Use with Fine Beam Tube Argentina (Buenos Aires), Helmholtz Coils for Use with Fine Beam Tube Armenia (Yerevan), Helmholtz Coils for Use with Fine Beam Tube Australia (Canberra), Helmholtz Coils for Use with Fine Beam Tube Austria (Vienna), Bahrain (Manama), Bangladesh (Dhaka), Bhutan (Thimphu), Bolivia (Sucre), Botswana (Gaborone), Brazil (Brasília), Brunei (Bandar Seri Begawan), Montenegro (Podgorica), Morocco (Rabat), Mozambique (Maputo), Myanmar (Naypyidaw), Namibia (Windhoek), Nepal (Kathmandu), New Zealand (Wellington), Nigeria (Abuja), Oman (Muscat), Palestine (Ramallah), Panama (Panama City), Papua New Guinea (Port Moresby), Paraguay (Asunción), Peru (Lima), Philippines (Manila)¸ Portugal (Lisbon), Qatar (Doha), Rwanda (Kigali), Saudi Arabia (Riyadh), Senegal (Dakar), Serbia (Belgrade), Sierra Leone (Freetown), Slovakia (Bratislava), South Africa (Cape Town) (Pretoria) (Bloemfontein), South Sudan (Juba), Spain (Madrid), Sri Lanka (Sri Jayawardenepura Kotte) (Colombo), Sudan (Khartoum), Syria (Damascus), Tanzania (Dodoma), Thailand (Bangkok), Togo (Lomé), Tonga (Nuku'alofa), Trinidad and Tobago (Port of Spain), Tunisia (Tunis), Turkey (Ankara), Turkmenistan (Ashgabat), Uganda (Kampala), United Arab Emirates (Abu Dhabi), United Kingdom (London), United States (Washington, D.C.).

A spring clip on the top crossbar is used to mount the Hall sensor during measurements of the magnetic field.
The Pair of Helmholtz coils is used for generating a homogeneous magnetic field and for the determination of the specific charge of the electron e/m in conjunction with the dual-beam tube. 
The coils can be switched in parallel or in series. 
The maximum field strength generated by the coils (~ 4 mT) is approximately 750 times weaker than that produced by an machine (~3 T), which are known to be safe Scince Lab Supplies for use by people with medical implants such as pacemakers.
• Number of turns per coil: 124
• DC resistance: 1.2 ohms each
• Coil Dimensions (Dia.): 295mm
• Coil spacing: 150 mm
• Maximum flux density at 5 A: 3.7 mT
• Weight: 4.1 kg approx.
• Maximum coil current: 5 A
• Maximum coil voltage: 6 V